Panel PC for Metro Station Equipment: PSD, TVM, Gates

At 06:40 the platform is already busy, and three pieces of equipment decide whether the morning works: the platform screen doors, the ticket machines in the concourse, and the gates between them. Each has a controller, each controller has a cabinet, and most cabinets have a screen in them. That screen is where a panel PC earns its place — not as a monitor, but as the terminal that reads door states, counts tickets and logs gate alarms.

The OPC series is a fanless embedded panel PC built for that job: nine sizes from 15 to 32 inches, IP65 front face, 10-point capacitive panel, -10 °C to 60 °C. It mounts into a cutout rather than onto a bracket, which is what a station cabinet needs.

Panel PC embedded in a stainless steel platform screen door control cabinet on a metro platform, showing door states and next train

Three cabinets, three different jobs

Platform screen doors. The PSD control cabinet sits at the platform end or in a nearby equipment room. Inside, a door control unit drives the door pairs and reports back: position, locked confirmation, obstruction, bypass, and the interlock state that lets a train depart. The panel PC here is the local HMI — the screen an attendant looks at when a door pair fails to close and the train is holding. It has to show the whole platform line at once, which is why 15.6 or 21.5 inch landscape is the usual choice, and it has to keep working when the link to the station server is down, because the interlock does not wait for a server.

Ticket vending machines. A TVM is a smaller cabinet with more devices inside it: note acceptor, coin hopper, printer, dispenser, card reader, and a passenger-facing screen. The panel PC in the upper section runs the fare logic and the payment state machine, then pushes the transaction upstream. The constraint here is depth and heat rather than size — the unit sits among four other heat sources in a sealed box, and it is the one component that cannot have a fan pulling ticket dust through it.

15.6 inch panel PC inside a metro ticket vending machine with the service door open, fare map and ticket options on screen

Fare gates. The gate controller lives in the end pedestal of a lane bank. It reads cards and QR codes, drives the barriers, counts passages and reports faults. The screen is staff-facing: lane state, reader health, passage counters, the last few alarms. Fifteen point six inches is usually enough; what matters is readability at an angle from standing height, and a touch panel that survives being cleaned several times a day.

Panel PC in the end pedestal of a metro fare gate bank showing lane state, passage counts and alarms

One screen standard across all three means one spare part, one OS image, one set of commissioning notes. That is the real case for a single panel PC family.

What the platform does to a display

Brake dust is the first problem, and it is not ordinary dust: fine, dark and mildly conductive, it settles on every horizontal surface and gets into anything with an air path. A fan-cooled terminal pulls it through the heatsink; the OPC has no fan and no intake, so the chassis is a closed aluminium box with heat leaving through the walls.

Cleaning is the second. Platform equipment is washed with alkaline detergent and wiped constantly, and a screen in a public area takes the same treatment as the stainless around it. The front face is IP65 — sealed against dust and against water jets from any direction. That is what makes the washdown possible.

Temperature is the third, and it moves faster than most specifications assume: the piston effect of every train, doors opening to the tunnel, a sun load in a glazed concourse. The OPC is rated -10 °C to 60 °C operating, -20 °C to 70 °C in storage, at 5% to 95% relative humidity without condensation. Those numbers cover a station in most climates, but they are ambient ratings for the unit: measure inside the cabinet, not in the room, and check again in August with the doors closed.

Vibration and EMC rarely reach a datasheet conversation. The unit is solid-state and clamped into a steel cabinet, so train-induced vibration is a mounting question: the cutout and clamp frame must be rigid and the cabinet anchored. On EMC, the unit is tested against electrostatic discharge, which matters in a dry station in winter. If the tender names a specific railway standard, that is a separate report and a generic ESD test does not cover it — ask before the tender closes.

IP65 on the front, open at the back

An embedded panel PC is two products in one housing. The front is a sealed membrane over glass, gasketed into the bezel, rated IP65. The back is a steel box with connectors, convection vents and a mounting plate, living inside the cabinet where nobody washes anything.

Design the cabinet for that split. The cutout needs a clean, flat, unpainted land — a gasket sealing onto a powder-coated face with a burr on it will leak. The rear needs clearance for connectors and cable bend radius, and it needs the cabinet's own ventilation, because the panel PC's heat has to go somewhere now that the cabinet is the enclosure. A sealed, unventilated cabinet will sit 10 to 15 K above the platform in summer, and no unit rating survives that.

Condensation surprises people. A cold cabinet opened on a humid morning, or a unit moved from air-conditioned storage to a warm platform, pulls moisture onto a cold board. Power up after it has equalised; keep the cabinet's desiccant or heater working.

Rear of a panel PC inside a control cabinet, with DC 12 V, LAN, USB and earth connections wired to terminal blocks on DIN rail

The port list decides the integration

The default interface is short and worth reading precisely: wide-voltage DC 12 V input, optional 9–36 V, one HDMI, one VGA, four USB, one RJ45 LAN, audio in and out. Enough for a TVM or a gate controller. Not automatically enough for a PSD cabinet, and the reason is serial.

Door control units and older gate controllers frequently speak RS485 or RS422, and there is no DB9 in that list. Two honest routes: an isolated USB-to-RS485 converter, which works but adds a component and a driver to validate, or native COM ports specified at order time. Decide before the cabinet drawing is fixed — it changes the cable schedule and the gland plate.

Storage and expansion depend on the board generation. Up to the 5th generation: one mSATA plus one SATA, expansion through Mini PCIe. 6th generation and later: one M.2 plus one SATA, an M.2 E-key slot for WiFi and Bluetooth, and an M.2 B-key slot for a 4G or 5G module. A 2.5 inch drive up to 2 TB fits either way. For a station terminal that means a small SSD for the OS and application, and a separate path for logs if the operator wants them kept locally.

The single LAN port is the constraint people miss. A station terminal often needs two networks: the equipment VLAN for the controller, the station LAN for the management platform. With one port you separate them upstream through a managed switch and a small VLAN-aware router in the cabinet — cheap, and it works, but it is a cabinet decision rather than a commissioning surprise.

Memory runs 4 GB to 32 GB depending on board; processors run from Celeron J1800 and J1900 to Core i3, i5 and i7 across 3rd to 10th generation. Specify by what the application does, not by the biggest number in the list.

Screens that get touched with wet hands and gloves

Ten-point capacitive touch is right for a public terminal, but be precise: it responds to a finger, a thin nitrile glove or a capacitive stylus. It does not respond to a thick winter glove, and it does not behave like a resistive panel with a wet glove. If attendants work in heavy gloves on an open platform, say so at specification stage — 10.4, 12.1, 15, 17 and 19 inch resistive versions exist for that reason, and they cost more.

Size is a viewing-distance question. At a PSD cabinet the attendant stands a metre back and needs the whole door line visible: 15.6 inch is the minimum, 21.5 inch is comfortable. At a gate pedestal the operator is close and the data is tabular, so 15.6 inch is enough.

Stations lose their network link more often than the public imagines: maintenance windows, switch replacements, a fibre hit during adjacent works. A terminal that only writes to a server loses the shift.

The pattern that works is local-first: write the transaction or event to local storage, mark it pending, and let a small uploader drain the queue when the link returns. The 4G module in the M.2 B-key slot covers a station that wants a path independent of the station LAN. The queue logic itself belongs in the application, and in the acceptance test.

21.5 inch panel PC on a station control room desk showing platform crowding index, next trains and equipment alarms

Maintenance in a station that never closes

The service window is a few hours and it is not the same few hours every week. That shapes the design more than any specification figure.

A fanless unit removes the most common wear item and the filter changes that go with it. What remains is the storage device, the OS image and the CMOS battery. Build the commissioning image so a replacement is a drop-in: same OS build, same IP, same application version, restored from a USB stick. Remote diagnostics and program updates cover the rest — most faults here are application faults and can be cleared from the control room.

Keep one spare of the most common size in the depot. Screens that fail in service are usually damaged rather than worn out: an impact on the glass, a hose into a tired gasket. A spare turns a two-week procurement into a forty-minute swap.

Specifications

Item

Specification

Screen sizes

15 / 15.6 / 17 / 18.5 / 19 / 21.5 / 23.6 / 27 / 32 inch

Resolution

1024×768 (15 in); 1280×1024 (17, 19 in); 1366×768 (15.6 in); 1920×1080 (18.5 in and above)

Touch

10-point capacitive; resistive versions on 10.4 / 12.1 / 15 / 17 / 19 inch

Front protection

IP65, dust-tight and resistant to water jets; corrosion and moisture resistant

Processor

Intel Celeron J1800 / J1900; Intel Core i3 / i5 / i7, 3rd to 10th generation

Memory

4 GB / 8 GB / 16 GB / 32 GB, board dependent

Storage

mSATA + SATA up to 5th gen; M.2 + SATA from 6th gen; 2.5 in drive up to 2 TB

Expansion

Mini PCIe (WiFi/BT or 4G) up to 5th gen; M.2 E-key 2230 + M.2 B-key 4G/5G 3052 from 6th gen

Default I/O

1 × HDMI, 1 × VGA, 4 × USB, 1 × LAN, audio in / out

Serial

Not in the default port set; COM board on request

Power input

DC 12 V wide voltage; 9–36 V optional

Operating temperature

-10 °C to 60 °C

Storage temperature

-20 °C to 70 °C

Humidity

5% to 95%, non-condensing

Operating system

Windows 7 / 8 / 10, Linux, Android

Mounting

Embedded cutout, wall mount, desktop

Weight

Approx. 3.7 to 12.5 kg depending on size

Specifying one for a station: five answers

  1. The cutout drawing. Opening dimensions and flange flat width. The OPC comes in nine sizes from 15 to 32 inch with published cutouts, but the gasket needs a flat land, and a drawing answers that faster than a datasheet. The method is set out in the notes on measuring a panel PC cutout.

  2. The interface list, device by device. Every controller, with its protocol: RS485 two-wire or four-wire, RS232, Ethernet, USB. That list decides whether you need a COM board or a converter, and it decides the cable schedule.

  3. The power available. DC 12 V is standard, 9–36 V is the option. Station cabinets often run 24 V DC or a UPS-backed supply, and the wide-range input avoids a separate converter with its own failure mode.

  4. The standard named in the tender. IP65 is a product rating. If the authority requires a specific EMC, fire-performance or material standard for tunnel equipment, name it at enquiry stage so the right report is quoted.

  5. The OS and the image. Windows 10 IoT Enterprise LTSC or Linux are the realistic choices for a ten-year station life, and both are supported. Android is available where the application is built for it. Ship the image pre-installed.

With the cabinet drawing and the interface list, send them to our engineers and we will come back with size, cutout and port configuration in one pass instead of three rounds of questions.

FAQ

Is the whole unit IP65?

No. The front panel is IP65, sealed against dust and water jets; the rear housing sits inside the cabinet and is not rated for washdown. That is normal for embedded panel PCs, and why the cabinet design matters as much as the panel.

Will it run at 60 °C?

The range is -10 °C to 60 °C ambient at the unit. Inside a closed cabinet the ambient is higher than on the platform, so measure the cabinet and keep the rear in moving air.

Can it talk to an RS485 door controller out of the box?

Not with the default port set, which has no serial. Use an isolated USB-to-RS485 converter, or specify native COM ports with the order — the second option is cleaner for a system that will be maintained for a decade.

Which size for a platform screen door cabinet?

15.6 inch is the practical minimum for a full door line; 21.5 inch is comfortable where the attendant stands back. Both are 16:9 and both fit a standard cutout with a flat gasket land.

Can we have our own branding and a pre-loaded image?

Yes. The OEM panel PC programme covers laser-engraved logo, BIOS and OS pre-installation, and industrial protective packaging — usually the difference between a box and a commissioned terminal on a station roll-out.

The short version

Metro station equipment is not harsh the way a foundry is. It is dirty, vibrating, electrically noisy and publicly accessible, and the terminal in the cabinet has to be boring for a decade. A sealed front, a fanless body, a cutout that seals, and a port list that matches the controllers are the whole specification. Everything else is packaging.

The OPC series runs from 15 to 32 inch with IP65 front protection, 10-point capacitive touch, DC 12 V or 9–36 V input, and boards from Celeron to 10th generation Core. If you are specifying a station terminal, start from the industrial panel PC range, work outwards from the cabinet, then send us the drawing.

Meet ELEC Ltd focuses on R&D and supply of industrial electronic equipment, including industrial PCs, touch all-in-ones, rugged tablets, interactive displays and servers. Our products feature stable performance, industrial-grade quality, ideal for various industrial application scenarios worldwide.

Quick Links

Product Category

Contact Us

 Tel: +86-18028100582
 Email: rosa@gdvincanwo.com
 Add: Building 1, Zhongji High-tech Intelligent Manufacturing Center, No. 3, Chanxing 1st Road, Xianyong Village, Chencun Town, Shunde District, Foshan City, Guangdong Province, China

Subscribe To Our Newsletter

Leave a Message
Copyright © 2026 Foshan Lineng Electronic Equipment Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy