OPC is a 15-inch panel PC built around one decision: the screen stays 4:3 at 1024 × 768. On a CNC or a legacy HMI that means the WinCC, InTouch or machine-builder screen lands pixel for pixel — no stretching, no black bars, no re-authored layouts. The front is a seamless IP65 face of tempered glass over an aluminium bezel with a moulded gasket, so coolant mist and metal debris stay outside the panel.
Behind it sits a fanless X86 board running from Celeron J1900 to a 12th-gen Core i5-1235U, with DDR3 or DDR4 memory, mSATA or M.2 NVMe storage up to 1 TB, Gigabit LAN, two isolated RS232/485 DB9 ports, four USB, HDMI plus VGA, and a DC 9–36 V input terminal for cabinets where the rail is not a clean 12 V. It mounts four ways: snap-in flush, VESA 75/100, desktop stand or cantilever arm.
| Availability: | |
|---|---|
OPC-15"
Meetneng
OPC is what goes into the door of a control cabinet on a production line: a 15-inch 4:3 touch panel with the computer inside the same housing, an IP65 front face, and a rear that is meant to be wired once and left alone. It is not a monitor with a mini PC taped to the back, and it is not a consumer tablet in a metal frame — it is one part number that a maintenance engineer can swap in an afternoon.
That framing decides everything below. The resolution is chosen for existing HMI projects rather than for video. The front is sealed because the machine next to it uses coolant. The power input accepts 9–36 V because cabinet rails are not always clean. And the mounting options exist because the same unit has to serve a new build and a retrofit of a machine that has been running since 2014.
Put a 4:3 HMI project on a 16:9 panel and one of two things happens: it is stretched horizontally until circles become ellipses and text kern is wrong, or it is letterboxed with black bars and the bottom row of buttons sits below the bezel. Both are visible to an operator within a second, and the second one is a safety problem when the row that disappears holds a stop or a reset.
A native 1024 × 768 panel has neither problem. Every pixel the software addresses is a pixel the panel shows, the button geometry the integrator drew in 2009 still lands under the same finger, and no one has to re-author a screen that is validated and signed off. If your project is genuinely authored for 1920 × 1080, tell us — we will quote a 16:9 model instead of selling you a 4:3 panel with a compromise attached.
The IP65 rating on the front is not a coating. It is a construction: a tempered glass sheet bonded over the display, a moulded rubber gasket compressed between that glass and the aluminium front bezel, and a bezel that meets the cabinet door flush. Water, coolant mist, oil and fine metal debris hit a continuous surface with no seam to pool in.
The glass is specified as oil and coolant repellent, which in practice means droplets bead instead of filming the screen — the difference between an operator who can read a trend at arm's length and one who wipes the panel every ten minutes. The rating is a front-face rating; the rear housing must still breathe and be reachable for cabling, so mounting method and enclosure design decide what the back of the panel sees.
The rear of the panel is where the architecture happens. A field network reaches PLCS, sensors, I/O modules and servo drives over industrial Ethernet; a second segment carries the same data up to MES for production management, reporting and monitoring; and where the plant allows it, an outbound path feeds a cloud platform for storage, remote monitoring and predictive analysis. Keeping those segments physically separate on different NICs is the difference between a tidy network drawing and a broadcast storm that stops a line.
The compute behind it is an X86 board chosen by workload, from Celeron J1900 for a fixed HMI screen up to a 12th-gen Core i5-1235U for edge analytics, local databases and several applications at once, with DDR3 or DDR4 memory and M.2 NVMe storage up to 1 TB. Tell us what runs on it and how many network segments you need, and we will match the board instead of quoting the top of the range by default.
The connector row is deliberately conventional: a two-pin DC terminal that accepts 9–36 V, HDMI, VGA, four USB, Gigabit LAN, audio in and out, and a keyed power switch. Nothing here needs a proprietary cable, which matters when a line has to be back up on a Sunday and the only spares are what is in the maintenance cupboard.
Serial is the part worth reading twice. COM1 and COM2 are isolated DB9 ports configurable as RS232 or RS485: RS232 keeps DCD, RXD, TXD, DTR, GND, DSR, RTS, CTS and RI on the standard pin map, while RS485 uses pins 3 and 4 for 485+ (A) and 485− (B) with the rest not connected. Isolation is what keeps a ground potential difference between cabinet and machine from taking out the port — send us the device list and we will map pins to devices before you crimp anything.
Snap-in flush mounting uses quick clamps and leaves the front sitting level with the cabinet door. VESA 75 × 75 or 100 × 100 covers wall and plate mounting. A desktop stand with −5° to 60° tilt turns the panel into a workstation. A cantilever arm puts it in front of an operator who has no cabinet at all.
The arm is where physics enters. Load is carried at the wall or column point, the arm has a load centre, and the further the panel sits from that point the higher the moment on the fixings and on the door. A 15-inch panel is light enough that most arms are fine, but if the panel goes on a swinging door or a thin sheet-metal column, tell us the thickness and the reach — we will send the fixing detail rather than let the installer discover it.
A 250-nit panel is readable in a dim control room and turns into a mirror next to a window or under a high-bay luminaire. At 350 nits the same screen keeps its contrast with ambient light falling on it, which is the normal condition on a shop floor — and the difference is not a spec-sheet argument, it is whether an operator has to shade the screen with a hand to read an alarm.
The panel is IPS with a 178° full view, 89° to each side, so a second person standing beside the operator reads the same values without a colour shift. It is not a sunlight-readable display and we will not sell it as one: outdoors, or in direct sun through glass, it will wash out. Tell us where the panel is going and we will say plainly whether 350 nits is enough for that position.
The common job for this model is replacing a dead 15-inch 4:3 panel on a machine that is otherwise fine. The cutout is 349.4 × 277.7 mm and the outer size is 358.4 × 286.7 mm — measure the existing aperture and the flange area, and the swap is mechanical: unclamp, lift out, drop in, clamp, reconnect power and serial, restore the HMI project.
What turns an afternoon into a week is discovering that the old unit had a 350 mm cutout, or that the door is 2 mm thick where the clamps need 3 mm, or that the HMI project lived on a hard drive nobody imaged. Send us the aperture drawing and the machine model before you order, and ask the machine builder for the project file — those two documents decide the schedule far more than the panel does.
The advantage sheet lists Intel multi-core performance, IP65 front protection, −10 to 60 °C operation, accurate 10-point capacitive touch, EMC anti-interference testing and 24/7 fanless silent operation. Each one maps to something concrete: an X86 board from J1900 to i5-1235U; a glass-gasket-bezel front; a temperature range we will confirm against your mounting point; a touch layer specified for gloves; an EMC-tested build; and a housing with no fan and no filter to service.
Where a claim needs a condition, we say so rather than let the sheet stand alone: the temperature range assumes the panel is not heat-soaked in a sealed box or in direct sun; the touch performance depends on the glove; and EMC compliance is a property of the tested build, not of the chassis alone — a custom board or an added radio changes the test scope. Tell us which claims your tender actually requires evidence for, and we will send the corresponding documents.
This panel is the wrong buy for three cases: a new machine whose HMI is authored for 1920 × 1080; a camera wall or a multi-column MES dashboard where width is the point; and any position where the screen sits in direct sunlight, because 350 nits will not survive it. In those cases a 15.6, 18.5 or 21.5-inch 16:9 panel is the honest recommendation, and quoting this model would only move the problem to commissioning.
For everything else, three answers decide the configuration: the aperture or mounting method, the devices that connect (and whether any of them need RS485), and the software that has to run. Send those three and we will return a configuration, a cutout drawing and a lead time — with the temperature and certification evidence your project needs attached.
Item | Specification |
|---|---|
Model | OPC |
Product type | 15" 4:3 fanless industrial touch panel PC, embedded |
Display | 15.0" TFT, native 4:3, 1024 × 768 |
Brightness | 350 cd/m² |
Viewing | IPS, 178° full view (89° each side) |
Touch technology | 10-point projected capacitive |
Touch mode | Finger and work glove |
Processor | Celeron J1900 · Core i3 / i5 / i7 · 12th-gen Core i5-1235U |
Memory | DDR3 or DDR4, 4 GB–16 GB (32 GB on selected boards) |
Storage | mSATA / M.2 NVMe / SATA, up to 1 TB |
Ethernet | Gigabit LAN — 1 / 2 / 4 ports depending on board |
Serial | 2 × isolated DB9, RS232 or RS485; up to 6 by configuration |
USB | 4 × USB |
Display output | 1 × HDMI + 1 × VGA |
Audio | 1 × audio in, 1 × audio out |
Power input | DC 9–36 V wide voltage, 2-pin terminal |
Front protection | IP65 seamless front (front face only) |
Front construction | Tempered glass + moulded gasket + aluminium bezel |
Cooling | Fanless, aluminium housing |
Operating temperature | −10 °C to 60 °C |
Duty cycle | 24/7 continuous operation |
Mounting | Snap-in flush / VESA 75·100 / desktop stand / cantilever arm |
External size | 358.4 × 286.7 mm |
Cutout size | 349.4 × 277.7 mm |
Operating system | Windows 7 / 10 / 11; Linux — confirm per build |
Certification | CE, FCC, RoHS; EMC tested; ISO 9001 factory |
Warranty | 3 years |
Meetneng traces its manufacturing back to 2008, and designs and builds in Shunde, Foshan, Guangdong — the district that supplies much of China's appliance and electronics industry. The plant covers 5,000 m², and the work is not assembled from someone else's boxes: sheet-metal fabrication, board-level integration, system assembly, burn-in and software imaging all happen on the same site. That is why a change to a port layout, a housing or a nameplate can be answered with a date rather than an introduction to a third party.
The product range covers industrial panel PCs, fanless industrial PCs, embedded computers, rugged tablets, industrial displays and commercial self-service terminals — panel-mount, VESA, DIN-rail, desktop and floor-standing formats from one factory. Quality control runs to ISO 9001 with twelve inspection points from incoming components to the final functional test, and the field repair rate is held under 0.5 % — a number that matters more than any single specification on any one of those pages.
Thirty-plus patents are held by the engineering team, covering thermal design, structural details and the interface between the electronics and the enclosure. Units are issued with CE, FCC, LVD and RoHS documentation against the exact bill of materials of the build you order, because changing a radio module or a power supply changes the test scope.
More than 15,000 customers in over 100 countries have bought from us, across industrial automation, energy, medical equipment, security, retail and logistics. Reference accounts include Haier, Gree, BYD, Hikvision, Foxconn and CRRC. Most of those relationships began with a single unit on a single line, which is the pattern we plan for: the first sample has to be right, because the second conversation depends on it.
Trade happens in person as well as over email. We take our own stands at international industrial and electronics fairs — the collage below is our booths across several shows — and the engineers who answer an enquiry are often the ones standing there, so a specification question tends to get an answer on the spot rather than a promise to check. Between shows, buyers come to Shunde to walk the line, sign off a sample and agree packaging. Tell us when you are travelling and we will hold a slot and a sample build for the same week.
OEM and ODM are the default way we work rather than an exception. The engineering team takes a requirement list — CPU or SoC, memory, port count, enclosure, logo, packaging, software image — and returns a configuration and a lead time. The nameplate, boot logo, gift box and manual are the parts most buyers start with, and the SDK or driver documents are released to the account that orders the sample.
Units ship by express and air freight with export documentation and industrial protective packaging; stocked configurations leave within 72 hours and built-to-order units follow the lead time on the quotation. Tell us the application, the destination country and the annual volume, and we will come back with a configuration, a landed-cost estimate and a sample plan.
Model OPC: a 15.0-inch native 4:3 panel at 1024 × 768, 350 nits, IPS with 178° full view. It is not a 16:9 panel, and that is deliberate — an existing WinCC, InTouch or machine-builder project shows on it pixel for pixel. If your project is authored for 1920 × 1080, tell us and we will quote a 16:9 model instead.
The cutout is 349.4 × 277.7 mm and the outer size is 358.4 × 286.7 mm. Send the aperture drawing of the existing door and we will compare the numbers, including the corner radii and the door thickness the clamps need. A small difference is usually a clamp or a spacer question — but it has to be measured, not assumed.
Yes, the front face is IP65: tempered glass over the display, a moulded gasket compressed against the aluminium bezel, and a bezel that sits flush in the cabinet cutout. That is what keeps coolant mist, oil and metal debris out. It is a front-face rating — the rear housing has to breathe and be reachable for cabling, so ask us about rear protection if the back of the door is washed down.
Two isolated DB9 ports as standard, configurable as RS232 or RS485, expandable to six by configuration. Isolation protects the port when there is a ground potential difference between the cabinet and the machine. RS485 uses pins 3 and 4 for 485+ and 485−; the rest are not connected. Send the device list with signal types and we will map it for you.
Yes, on boards with two NICs — one segment for the machine and field devices, one for MES or the plant network, and optionally an outbound path to a cloud platform. Four-port editions cover cells that need more isolated segments. Tell us how many segments you need and what hangs off each, and we will confirm the board.
For indoor machine halls, cells and control rooms, yes — it holds contrast with ambient light on the screen, which a 250-nit panel does not. It is not sunlight-readable: outdoors or in direct sun through glass it will wash out. Tell us the position and the lighting and we will answer for that position rather than in general.
A fixed 1024 × 768 runtime with trends, alarms and recipes runs comfortably on J1900 or a low-power i3. i5 and the 12th-gen i5-1235U are for edge analytics, local databases or several applications at once. Send the software name and version and whether it keeps a local historian, and we will size the board to it.
Fanless, aluminium housing, no filter to change, rated −10 °C to 60 °C for 24/7 duty. What breaks the rating in practice is heat soaking — a sealed enclosure, direct sun on a metal door, or no air movement around the rear. Tell us the mounting conditions and the measured ambient at the panel, not the plant average.
Four ways: snap-in flush with quick clamps, VESA 75 × 75 or 100 × 100, desktop stand with −5° to 60° tilt, and cantilever arm. The arm carries load at the wall or column point, so reach and door thickness matter more than panel weight. Send the mounting surface and the reach you need and we will send the fixing detail.
Three years standard on OPC — note that our POS terminals carry one year, so do not carry the number across product lines. Customisation covers logo silk-screen, boot screen, BIOS information, packaging, and I/O or software-image changes under ODM. Send the artwork, the port list and the target quantity and we will confirm the lead time.