This screen is not built to be sat in front of. It is built to hang: from a roof truss over a walkway, from a gantry above a line, from a bracket on a column, in a workshop where the nearest person is six metres away and the furthest is twenty. At 770.7 mm across and 12.5 kg of sheet metal, it is a piece of rigging as much as a display.
That changes the whole specification. Legibility is set by the farthest worker, not the nearest finger; colour has to survive sodium and LED lighting and a dirty screen; and somebody has to sign off that the truss or bracket will hold 12.5 kg with a person walking underneath it. 1920 × 1080 across 32 inches is 68.8 PPI — coarse on a desk, and exactly right for an andon read from ten metres.
| Availability: | |
|---|---|
OPC-32"
Meetneng
An andon board is read while walking, from underneath and at an angle, with a cap brim in the way. That is a different optical problem from a screen at desk height: the viewer is looking up and across, the light is a mix of skylight and high-bay LED, and nobody is going to walk over and adjust the brightness.
So the requirements stack in an unusual order. Mounting and safety come first, because a 12.5 kg panel over a walkway has to be signed off. Viewing distance comes second, because it sets how large the type can be before the screen is wasted. Touch comes last — on this size it is a commissioning convenience, not the way the line is run. Tell us the mounting height and the walkway layout and the rest of the specification follows.
The housing is a folded steel box quoted at about 12.5 kg. Hung from a roof truss or a gantry rail, that load goes through a VESA 100 plate and two or four bolts into whatever the building has. A truss chord rated for lighting may not be rated for a 12.5 kg panel with a moment arm, and the person who signs that off is not the person buying the screen.
Three practical requirements come out of it. The bracket and its fixings must be rated above the panel weight with margin, not at it. A secondary safety cable is mandatory on any overhead installation — the housing has a lock point for it, and we supply the eye bolt. And the cable route must be supported independently of the panel, so a pulled network lead cannot load the bracket. Send us the truss or bracket rating and the mounting height and we will confirm what the installation needs.
At 68.8 PPI the pixel is 0.37 mm. On a desk that is visibly coarse; at ten metres it subtends about 0.13 arc-minutes and the eye gives up on individual pixels entirely — which is precisely the point. A 32-inch board at that distance is read as station blocks, colour states and a takt timer, not as a table of numbers.
That is a design rule, not a limitation. Station tiles should be at least 120 mm on screen, status colour should be the loudest thing on the panel, and the biggest type should be the thing that stops the line — the call, the alarm, the beat. Text below about 14 mm cap height is wasted at ten metres and only useful to the supervisor standing underneath. Send us the layout you plan to run and we will say what survives the distance.
Nobody climbs a ladder to tap an andon board. The ten-point capacitive layer here exists so that an engineer can bring up a diagnostic page, change a line assignment or acknowledge an alarm during setup, without a laptop balanced on a rail. Day to day the board runs untouched, driven by MES and PLC data.
That has two consequences worth stating plainly. First, the touch layer is not the reliability risk it would be on a machine HMI, so the specification emphasis sits on the glass — ≥7H, anti-glare, cleanable — rather than on glove compatibility. Second, if the board is mounted out of reach, say so: a build without touch is cheaper and one less thing to fail. Tell us whether anyone will actually reach it.
The truss or gantry suspension is the standard for a walkway: a VESA 100 plate on the back, a drop bracket from the structure, and the panel hangs with its bottom edge above head height. The dual-joint arm suits a column or a machine frame where the board has to be swung aside for maintenance access. The flush snap-in is for a control cabinet or a wall where nothing may project.
All three use the same chassis and the same 100 × 100 pattern — this size does not offer VESA 75, so an existing 75 mm bracket needs an adapter plate. The flush route also needs the cabinet built to 765.6 × 460.3 mm with R7.5 corners, which is a sheet-metal decision made before the panel ships. Tell us which of the three the building already has.
The chassis measures 770.7 × 465.6 × 57.2 mm and the recommended opening is 765.6 × 460.3 mm with R7.5 corners. That leaves 2.55 mm of bezel at the sides and 2.65 mm top and bottom — thin enough that a wavy edge shows as a bright line against a dark screen, and thick enough that a clean routed edge disappears.
Two notes for a cabinet build. The 7.5 mm corners are structural: they stop the thin bezel cracking at a sharp internal corner, so the cut has to include them. And at 12.5 kg the panel is lifted into the opening by two people, which means the gasket takes a shear load on the way in — fit the snap-in clips before the final push, not after. Send the panel drawing before fabrication and we will mark the clearance, the radius and the clip positions.
The strip carries DC input, HDMI, VGA on a blue DB15, four USB-A in two stacked pairs, one RJ45, mic and line-out, and a metal power switch. The two blank plates at the left are cut for serial or a second network port when ordered.
On an overhead installation the wiring is a one-time job and the failure mode is mechanical, not electrical: a DC jack working loose over years of truss vibration, or a network lead hanging its own weight from the socket. Ask for the locking DC connector and a strain-relieved cable gland if the panel hangs over a press or a conveyor. Tell us what the board talks to and how the cable will be supported.
Three things surprise people on commissioning. Skylights. A panel that looked fine in the workshop shows a washed-out band at nine in the morning because the roof glazing lines up with the screen; the fix is an anti-glare treatment and a tilt of a few degrees, not a brighter panel. Second, distance: the layout that worked on a desk has too much small type at ten metres, and the first week is spent deleting columns.
Third, and most often missed: the board becomes the morning stand-up. Twenty people look at it at 07:55 and again at handover, which means it must show the previous shift as well as the current one, and it must not reboot into a login screen. Specify the boot behaviour and the shift view at order time. Tell us who runs the stand-up and what they need to see first.
Most andon installations should not compute on the panel at all. The board renders a browser page or a thin client session fed by the MES server, and a Celeron J1900 with 4 GB is enough — cheap, cool, and nothing to maintain at height. The heavier tiers exist for the sites that run the logic locally: a line controller that aggregates PLC tags itself, or a board that renders a 3D plant view on the panel.
Pick accordingly: J1900 or i3 with 4–8 GB for a thin client; i5 with 8 GB for local aggregation or a video wall of camera feeds; i7 with 16 GB only if the board renders something heavy. Storage runs 128–512 GB mSATA or M.2 NVMe plus a 1 TB bay for local logs, which is worth having when the network drops and the board must keep showing the last known state. Tell us where the data comes from and whether the panel must survive a network outage.
Mounting first: truss or bracket rating, height, and whether a safety cable is required by the site. Second, the network and data path, because it decides whether this is a thin client or a local controller. Third, the flush cut, if the board goes into a cabinet. The panel itself — touch or no touch, brightness variant, branding — is the cheapest thing to change and the last thing to argue about.
We quote the standard build and the customised build side by side, so the difference is visible rather than buried. Send us the mounting drawing, the MES or PLC interface and the shift pattern the board must display, and the quote comes back with those three answered.
Item | Specification |
|---|---|
Model | 32" 16:9 widescreen industrial panel PC |
Display size | 32 inch TFT LCD, 16:9 |
Native resolution | 1920 × 1080 (Full HD) |
Pixel density | 68.8 PPI, 0.37 mm pixel pitch |
Viewing angle | 178° (IPS) |
Brightness | On request — quoted against the selected panel |
Contrast | On request, quoted against the panel batch |
Touch technology | 10-point projected capacitive (for on-site configuration) |
Cover glass | Tempered glass, ≥7H, anti-glare treatment |
Processor | Intel Celeron J1900; Core i3 / i5 / i7, 3rd to 12th generation |
Memory | 4 GB / 8 GB / 16 GB DDR (16 GB maximum) |
Storage | 128 / 256 / 512 GB mSATA or M.2 NVMe SSD + 1 TB 2.5" SATA bay |
Graphics | Integrated Intel HD Graphics |
Network | 1 × Intel Gigabit Ethernet (RJ45); second port via expansion |
USB | 4 × USB-A on the bottom edge |
Serial | None on the standard edge; RS232 / RS485 via optional COM plate |
Video output | 1 × HDMI + 1 × VGA (independent dual display) |
Audio | 1 × mic in, 1 × line out |
Power input | DC 12 V standard; DC 9–36 V wide-range terminal optional |
Power draw | Quoted against the selected CPU (on request) |
Operating temperature | On request — wide-temperature build available |
Cooling | Passive convection through louvred backplate; fan specification per CPU |
Duty cycle | Continuous 7 × 24 h |
Ingress protection | IP65 front bezel; rear panel ventilated, not rated |
Mounting | VESA 100 × 100 gantry or dual-joint arm; flush snap-in; safety cable lock point |
Outline dimensions | 770.7 × 465.6 × 57.2 mm |
Panel cutout | 765.6 × 460.3 mm, R7.5 mm corners |
Mass | Approx. 12.5 kg gross per drawing; net weight confirmed per build |
Operating system | Windows 7 / 10 / 11, Windows IoT, Linux (drivers per SKU) |
Meetneng traces its manufacturing back to 2008, and designs and builds in Shunde, Foshan, Guangdong — the district that supplies much of China's appliance and electronics industry. The plant covers 5,000 m², and the work is not assembled from someone else's boxes: sheet-metal fabrication, board-level integration, system assembly, burn-in and software imaging all happen on the same site. That is why a change to a port layout, a housing or a nameplate can be answered with a date rather than an introduction to a third party.
The product range covers industrial panel PCs, fanless industrial PCs, embedded computers, rugged tablets, industrial displays and commercial self-service terminals — panel-mount, VESA, DIN-rail, desktop and floor-standing formats from one factory. Quality control runs to ISO 9001 with twelve inspection points from incoming components to the final functional test, and the field repair rate is held under 0.5 % — a number that matters more than any single specification on any one of those pages.
Thirty-plus patents are held by the engineering team, covering thermal design, structural details and the interface between the electronics and the enclosure. Units are issued with CE, FCC, LVD and RoHS documentation against the exact bill of materials of the build you order, because changing a radio module or a power supply changes the test scope.
More than 15,000 customers in over 100 countries have bought from us, across industrial automation, energy, medical equipment, security, retail and logistics. Reference accounts include Haier, Gree, BYD, Hikvision, Foxconn and CRRC. Most of those relationships began with a single unit on a single line, which is the pattern we plan for: the first sample has to be right, because the second conversation depends on it.
Trade happens in person as well as over email. We take our own stands at international industrial and electronics fairs — the collage below is our booths across several shows — and the engineers who answer an enquiry are often the ones standing there, so a specification question tends to get an answer on the spot rather than a promise to check. Between shows, buyers come to Shunde to walk the line, sign off a sample and agree packaging. Tell us when you are travelling and we will hold a slot and a sample build for the same week.
OEM and ODM are the default way we work rather than an exception. The engineering team takes a requirement list — CPU or SoC, memory, port count, enclosure, logo, packaging, software image — and returns a configuration and a lead time. The nameplate, boot logo, gift box and manual are the parts most buyers start with, and the SDK or driver documents are released to the account that orders the sample.
Units ship by express and air freight with export documentation and industrial protective packaging; stocked configurations leave within 72 hours and built-to-order units follow the lead time on the quotation. Tell us the application, the destination country and the annual volume, and we will come back with a configuration, a landed-cost estimate and a sample plan.
Yes, on a VESA 100 gantry bracket — but the truss or rail has to be rated for the panel weight with margin, and a secondary safety cable is required on any overhead installation. The housing has a lock point and we supply the eye bolt. Send us the truss rating and the mounting height and we will confirm the bracket and fixings before anything is lifted.
The drawing states about 12.5 kg gross, and the mounting artwork quotes 12.5 kg for the housing. Net weight is confirmed per build because CPU, memory and storage change it. For rigging, use the gross figure and add margin — do not design to the net number. Ask us for the weighing slip with the shipment if the site needs it in writing.
68.8 PPI is coarse at arm's length and correct at six metres and beyond, which is the distance an andon is read from. If this screen were going on a desk it would be the wrong panel. Tell us the nearest and farthest viewer and we will say whether 32 inches at 1080P is the right board or whether a smaller, denser panel would serve better.
Only if somebody will physically reach it. On an overhead andon the touch layer is used during commissioning — diagnostics, line assignment, alarm acknowledge — not during the shift. A build without touch is cheaper and one less component at height. Tell us whether the board will be within reach of a ladder or a platform.
The anti-glare treatment and 178° IPS panel hold colour from an angle, but brightness is quoted per panel batch and we will not guess at it. If the board faces roof glazing, say so: the answer is a high-brightness variant plus a mounting tilt, not a bigger screen. Send us a photo of the wall or truss position at the time of day the board matters most.
The panel keeps rendering whatever the local application holds, so the sensible build keeps the last known state on screen and marks it stale rather than going blank. That is an application decision, but it is worth making on the panel — a 1 TB local bay costs little and lets the board hold shift history through an outage. Tell us how long the site can tolerate a data gap.
Yes, and it usually should. The morning stand-up compares last shift with this one, so the layout needs a previous-shift column and a clear handover marker. That is a software layout decision, but it changes the panel size: a board that must show two shifts side by side needs more width than one that shows a single live state. Send us the layout and we will check it against 770 mm.
The front face, through a gasket behind the bezel. The rear backplate vents to the room and is not rated, which matters more overhead because dust settles on the top edge and washdown spray comes from below. Clean the front, leave the back alone, and mount it so the vents are not in the direct path of a hose. Tell us the cleaning regime in that bay.
765.6 × 460.3 mm with R7.5 corners leaves 2.6 mm of bezel, so it has to be routed or laser-cut — a jigsaw edge will show. The radius is structural and must be included. Send us the cabinet drawing before fabrication and we will mark the clearance, the radius and where the snap-in clips land.
Yes — bezel branding, a custom boot image, the OS image with your shell, and the I/O plate you need. For andon boards we also document the boot and recovery behaviour, because a board that stops at a login screen at 06:00 is a production problem. Send us the image and the shift behaviour you expect and we will quote both builds side by side.