At 656.7 mm this is the panel you stop calling a terminal and start calling a wall. It is bought for rooms, not desks: a command centre where three shifts hand over in front of the same screen, a plant control room where the digital twin is the object everyone points at, a dispatch desk where the alarm log has to stay visible while somebody talks on the phone.
Two numbers define it. 1920 × 1080 across 27 inches is 81.6 PPI — a 0.31 mm pixel, which is coarse at arm's length and correct at two metres. And the bezel is only 2.8 mm at the sides and 1.95 mm top and bottom, so the 651.1 × 394.2 mm opening with its 7.8 mm corner radius has to be routed, not sawn. Those two facts decide most of the project before the CPU does.
| Availability: | |
|---|---|
OPC-27"
Meetneng
A 27-inch panel in a control room is not a personal display. During a shift handover four or five people stand behind the chair, and during an incident the plant manager reads it from three metres away while pointing at something. The design constraint is therefore the back of the room, and that is a different calculation from the one used for a machine-mounted HMI.
Practically: at 2 m the 0.31 mm pixel subtends about 0.53 arc-minutes, close to the acuity limit, so the screen reads as continuous and the KPI numbers are unambiguous. At 3 m it is 0.36 arc-minutes and still legible for large type and colour state, but the alarm log text is for the near viewer only. Tell us the room dimensions and where people stand, and the layout follows from that instead of from a catalogue.
One more thing that only shows up in a room: the screen is read in glances, not in sessions. Somebody walks in, looks for one colour — red or green — and leaves. That is why the layout on a 27-inch wall panel should be built around state and trend, with the tables pushed to the edge for the person who actually sits there.
The installations behind this size share a habit: nobody watches one number. A packaging hall wants throughput, scan success and the status of four conveyors at once; a process plant wants the OEE dial beside the trend and the alarm log; a digital-twin room wants the plant model occupying half the screen while the rest argues about it.
That is why this panel is sold as a hub rather than a monitor. It carries the same 1080P canvas as the 23.6-inch unit, but at 656.7 mm the canvas is physically large enough that people stand back from it, and that changes the software: bigger type, fewer decimals, colour-coded state instead of dense tables. Send the screen you run today and we will say whether it survives the move to a wall.
1920 × 1080 across 27 inches gives 81.6 PPI and a 0.31 mm pixel. Up close that is visible structure — a macro photograph of the panel shows the pixel grid, and small type set at 100 % scaling looks soft. From two metres the same grid disappears and the argument for 4K collapses, because nobody standing there can resolve the extra detail.
So this size is honest about its job. Control rooms, dispatch desks, plant manager offices and wall positions at 1.5–3 m: correct. A designer reviewing CAD at 60 cm, or a workstation that also edits documents: wrong, and the 21.5-inch page is the better answer. Tell us the working distance and we will not sell you a bigger screen than the job needs.
Divide 1920 × 1080 by four and each pane is 960 × 540, which on this panel measures about 328 × 199 mm — wider than an A4 sheet held sideways. That is the practical argument for 27 inches: a pane that holds a plant schematic or an alarm table at a size somebody can read while standing.
The cost is GPU and memory, as on every quad layout. A 3D twin plus a trend plus a live alarm stream is an i5 workload with 8 GB; add camera preview or a database client and it becomes i7 with 16 GB. Tell us how many panes are live, whether any is video, and whether the twin is a real 3D scene or a static drawing — those three answers set the CPU line on the quote.
Two arrangements cover most rooms. Wall or cabinet mounting puts the panel at standing eye height where a group can see it, with the keyboard on a shelf below. A heavy cantilever arm puts it at the seated operator's height and lets it swing aside during maintenance. Both use the same chassis; only the interface changes.
Whichever you choose, the panel wants air behind it and a route for the cables that does not cross the desk. In a 7 × 24 room the screen is also on all night, so a panel that dims badly or drifts colour is noticed by the night shift first. Tell us the desk or wall arrangement and we will send the mounting drawing with the cable exit marked.
The arm is the honest option when the room is already built: a VESA 75 or 100 plate on the backplate, a heavy-duty gas-spring cantilever carrying the load, and the screen swings between the seated operator and the standing visitor. Nothing has to be cut, and the installation can be reversed in an hour.
The embedded frame is the option that looks permanent, and it has to be decided early — the cabinet is cut to 651.1 × 394.2 mm with R7.8 corners before the panel arrives. Choose it only if the wall or cabinet is being fabricated anyway; retrofitting means taking the cabinet apart. Both interfaces are on the same chassis, so nothing else in the specification changes. Tell us which one and when the steel is being cut.
The chassis is 656.7 × 398.1 × 51.3 mm and the recommended opening is 651.1 × 394.2 mm with a 7.8 mm corner radius. That leaves 2.8 mm of bezel at the sides and 1.95 mm at the top and bottom — a margin that hides a clean routed edge and nothing else. A jigsaw cut, a hand-marked line or a plasma edge with dross will show as a wavy black gap around a 27-inch screen, and everybody in the room will see it.
Two mechanical notes that matter at this size. The rounded corners are not decorative: they stop the thin bezel from cracking at a sharp internal corner, so the cutout must be routed or laser-cut with the radius included. And 51.3 mm of depth is tight for a VGA plug plus a DC jack bend — leave the bottom edge clear. Send us the panel drawing before fabrication and we will mark up the clearance and the corner radius.
The strip runs DC input, HDMI, VGA on a blue DB15, four USB-A in two stacked pairs, one RJ45, mic and line-out, and a metal power switch. Two blank plates at the left are cut for serial or a second network port when ordered; they are empty in the standard build.
The two arguments are always the same. First, the single Gigabit port: a control room that separates the plant network from the corporate one needs the second port as an ordered option, not as a switch in the cabinet. Second, VGA: it is there because the older inspection terminal in the corner is not being replaced this year, and a converter is a worse answer than a native port. Tell us the network segmentation and what still needs VGA and the connector schedule comes back filled.
The workload is a browser-class dashboard, a 3D twin, an alarm stream and sometimes a camera. Celeron J1900 runs one dashboard or a thin client to a server; i3 handles two or three panes; i5 is the sensible floor for a live 3D twin with a trend; i7 with 16 GB is for the room that also previews video or runs a local database. Memory runs 4, 8 or 16 GB, storage 128–512 GB mSATA or M.2 NVMe plus a 1 TB 2.5-inch bay for logs and snapshots.
Cooling is passive through the louvred backplate, which is the right choice for a room where people sit — but it also means the thermal budget belongs to the room, not to the datasheet. A 27-inch panel in a 24 °C control room and the same panel above a furnace line are two different quotations. Give us the ambient temperature, the pane count and the software, and the CPU is chosen once instead of twice.
Standard build: 1080P, IP65 front, single Gigabit port, passive venting, Windows or Linux on the customer image, VESA 75 / 100 and snap-in clips in the box. That covers most control rooms and it ships from a stock configuration.
The custom lines are predictable — brightness variant for a glazed room, second network port for a segregated plant network, serial for a legacy PLC link, bezel branding, and an OS image with the customer shell. One question is worth asking before the order: who reboots it. A wall-mounted panel with no keyboard needs a documented recovery path, either a remote KVM or a front-accessible USB, and that is cheaper to design in than to retrofit. Send us the panel schedule and the recovery plan and the quote comes back split along those lines.
Item | Specification |
|---|---|
Model | 27" 16:9 widescreen industrial panel PC |
Display size | 27 inch TFT LCD, 16:9 |
Native resolution | 1920 × 1080 (Full HD) |
Pixel density | 81.6 PPI, 0.31 mm pixel pitch |
Brightness | On request — quoted against the selected panel |
Contrast | On request, quoted against the panel batch |
Touch technology | 10-point projected capacitive, glove and wet-hand operable |
Cover glass | Tempered glass, ≥7H, anti-glare treatment |
Processor | Intel Celeron J1900; Core i3 / i5 / i7, 3rd to 12th generation |
Memory | 4 GB / 8 GB / 16 GB DDR (16 GB maximum) |
Storage | 128 / 256 / 512 GB mSATA or M.2 NVMe SSD + 1 TB 2.5" SATA bay |
Graphics | Integrated Intel HD Graphics |
Network | 1 × Intel Gigabit Ethernet (RJ45); second port via expansion |
USB | 4 × USB-A on the bottom edge |
Serial | None on the standard edge; RS232 / RS485 via optional COM plate |
Video output | 1 × HDMI + 1 × VGA (independent dual display) |
Audio | 1 × mic in, 1 × line out |
Power input | DC 12 V standard; DC 9–36 V wide-range terminal optional |
Power draw | Quoted against the selected CPU (on request) |
Operating temperature | On request — wide-temperature build available |
Cooling | Passive convection through louvred backplate; fan specification per CPU |
Duty cycle | Continuous 7 × 24 h |
Ingress protection | IP65 front bezel; rear panel ventilated, not rated |
Mounting | VESA 75 × 75 / 100 × 100 arm, embedded snap-in, desk console or wall |
Outline dimensions | 656.7 × 398.1 × 51.3 mm |
Panel cutout | 651.1 × 394.2 mm, R7.8 mm corners |
Bezel width | 2.8 mm left and right, 1.95 mm top and bottom |
Net weight | Confirmed per configuration (on request) |
Operating system | Windows 7 / 10 / 11, Windows IoT, Linux (drivers per SKU) |
Meetneng traces its manufacturing back to 2008, and designs and builds in Shunde, Foshan, Guangdong — the district that supplies much of China's appliance and electronics industry. The plant covers 5,000 m², and the work is not assembled from someone else's boxes: sheet-metal fabrication, board-level integration, system assembly, burn-in and software imaging all happen on the same site. That is why a change to a port layout, a housing or a nameplate can be answered with a date rather than an introduction to a third party.
The product range covers industrial panel PCs, fanless industrial PCs, embedded computers, rugged tablets, industrial displays and commercial self-service terminals — panel-mount, VESA, DIN-rail, desktop and floor-standing formats from one factory. Quality control runs to ISO 9001 with twelve inspection points from incoming components to the final functional test, and the field repair rate is held under 0.5 % — a number that matters more than any single specification on any one of those pages.
Thirty-plus patents are held by the engineering team, covering thermal design, structural details and the interface between the electronics and the enclosure. Units are issued with CE, FCC, LVD and RoHS documentation against the exact bill of materials of the build you order, because changing a radio module or a power supply changes the test scope.
More than 15,000 customers in over 100 countries have bought from us, across industrial automation, energy, medical equipment, security, retail and logistics. Reference accounts include Haier, Gree, BYD, Hikvision, Foxconn and CRRC. Most of those relationships began with a single unit on a single line, which is the pattern we plan for: the first sample has to be right, because the second conversation depends on it.
Trade happens in person as well as over email. We take our own stands at international industrial and electronics fairs — the collage below is our booths across several shows — and the engineers who answer an enquiry are often the ones standing there, so a specification question tends to get an answer on the spot rather than a promise to check. Between shows, buyers come to Shunde to walk the line, sign off a sample and agree packaging. Tell us when you are travelling and we will hold a slot and a sample build for the same week.
OEM and ODM are the default way we work rather than an exception. The engineering team takes a requirement list — CPU or SoC, memory, port count, enclosure, logo, packaging, software image — and returns a configuration and a lead time. The nameplate, boot logo, gift box and manual are the parts most buyers start with, and the SDK or driver documents are released to the account that orders the sample.
Units ship by express and air freight with export documentation and industrial protective packaging; stocked configurations leave within 72 hours and built-to-order units follow the lead time on the quotation. Tell us the application, the destination country and the annual volume, and we will come back with a configuration, a landed-cost estimate and a sample plan.
At 81.6 PPI the pixel is 0.31 mm, so at 60 cm you can see the structure and small type looks soft. At 2 m it subtends half an arc-minute and reads clean. This panel is built for the second distance. If the screen sits on a desk at arm's length, tell us and we will quote the 21.5-inch instead of selling you a blurry 27.
Yes — VESA 75 or 100 on the backplate, or snap-in clips for a fabricated cabinet. Standing eye height for a group view is usually 1.5–1.6 m to the centre of the screen, with the keyboard shelf below and the cable exit at the bottom edge. Send us the room height and where people stand and we will mark the height on the mounting drawing.
The front face only, through a gasket behind the bezel. The rear backplate vents to the room and is not rated, so wipe the front and never hose the back. In a cleanroom or a washdown area that distinction is the whole specification. Send us the cleaning routine and we will confirm the agents against the coating.
Weight is stated per configuration because CPU, memory and storage change it. For an arm the rated load matters more than our figure — send us the arm model and its load rating and we will check it against the actual build. A 27-inch panel on an arm bought for a 24-inch monitor sags slowly and nobody notices until it is at chest height.
Not well. 651.1 × 394.2 mm with R7.8 corners leaves 2.8 mm of bezel at the sides, which tolerates a routed or laser-cut edge and nothing else. The radius is structural — it stops the thin bezel cracking at a sharp corner. Send us the drawing before fabrication and we will mark the clearance and the corner radius.
Usually not, if the plant network and the corporate network are separate. The standard edge carries one RJ45 and the second is an ordered expansion on the blank plate. Tell us how many networks the screen touches and whether either is on a fixed VLAN, and the connector schedule comes back with the right count.
Depends on what is in them. Four browser-class dashboards run on i3 with 8 GB; a live 3D twin plus a trend plus an alarm stream wants i5 with 8 GB; add camera preview or a local database client and it becomes i7 with 16 GB. Tell us the pane count, whether any pane is video, and whether the twin is real 3D or a static drawing.
Yes — HDMI and VGA are independent outputs, so a second monitor or a wall display can carry a different view. It is a separate desktop rather than a clone, so the software must be told to open there. Tell us the second screen's distance and resolution; beyond about five metres HDMI needs an active cable or an extender.
A wall panel with no keyboard needs a recovery path designed in, and that is worth settling before the order: a remote KVM, a front-accessible USB, or a watchdog that reboots on a frozen process. We can document the recovery sequence for the customer's maintenance file. Send us the site support arrangement and we will draft it.
Yes — bezel branding, custom I/O, brightness variant and an OS image with your shell are normal ODM lines. We quote the standard and the customised build side by side so the difference is visible. Send us the logo file, the image and the annual volume and the quote follows.