This is the largest panel in the line and the only one that is natively 1080P. There is no 1366 variant to choose from, which removes the most common question in this category before it is asked: at 21.5 inches across 1920 pixels the density is about 102 PPI, so text drawn for a 1080P desktop is rendered at the size its author intended. An operator can run the vendor's software unmodified and see exactly what the developer saw.
The second decision is thermal. The chassis is fanless: a flat sheet-metal backplate with louvred slots, convection only, no impeller and no filter. That single choice decides where the unit may be installed — quiet rooms, dusty halls and areas where a fan would pull contamination into the cabinet are all fine, while a sealed box with no convection path is not. Body dimensions are 537.0 × 328.0 × 51.0 mm with a 529.0 × 320.0 mm cutout, IP65 across the front, −20 to 60 °C, rated for continuous duty.
| Availability: | |
|---|---|
OPC-21.5"
Meetneng
At 537 mm across, this panel does not go into a machine. It goes onto a desk, into a console frame or onto an arm in a room where somebody sits and watches a plant all day. The number that matters is not the diagonal but the footprint: a 529 × 320 mm opening, 51 mm of depth behind it, and enough clear space above the desk for the top bezel to be visible from standing height.
Getting the size right is therefore a layout exercise, not a specifications exercise. Tape the outline to the desk at the intended height, sit down, and check whether the KPI row at the top of your dashboard is inside comfortable eye travel. If it is not, no panel wins that argument. Send us a photo of the desk and a screenshot of the screen the operator watches and we will say which size fits it.
Every other size in this range offers a choice between a 1366-class panel and a 1080P one, and that choice drives price, software scaling and arguments inside the project team. This size does not offer it. The glass is 1920 × 1080 at about 102 PPI, which is the resolution most industrial software is now drawn for, so a modern dashboard lands at 100 % scaling instead of the 125 % that blurs fonts on a smaller panel.
Two consequences follow. Video and 3D content play at their native size, which is why digital-twin and vision-inspection screens look right on it. And legacy HMI software written for 1024 × 768 will look small in the middle of the canvas unless it is set to scale — the trade this size makes in exchange for not having a lower tier. Tell us the software and we will say which way to set it.
IPS earns its price when the second person arrives. One operator sits square to the panel; the shift lead, the auditor or the customer on a factory tour stands at the shoulder and looks in at forty degrees. At a 178° rating the image holds colour and contrast that far off axis, so a charts-and-KPI screen stays readable instead of washing out to grey — which a twisted-nematic panel at this size would do.
350 cd/m² is the other half of that answer. It is comfortable in a lit control room and adequate beside a window without direct sun; it is not a sunlight-readable panel and we will not pretend otherwise. If the console faces glazing, say so at enquiry — the answer is a high-brightness panel and a deeper anti-glare treatment, quoted as a variant rather than promised as a setting.
A 1920 × 1080 canvas divides cleanly into four panes of 960 × 540, and that is the layout these consoles actually use: a 3D plant view top-left, a camera or inspection result top-right, a work-order table bottom-left, telemetry or a trend bottom-right. Each pane is still larger than a 15-inch panel's whole screen area, which is the point — nothing is squeezed to make the layout fit.
The catch is that four live panes cost GPU and memory. A 3D scene plus camera preview plus two updating tables is not a Celeron workload once the windowing gets busy; i5 with 8 GB is the realistic floor for that layout, and i7 with 16 GB if the 3D view is dense. Tell us how many panes are live and whether any is video, and the CPU line on the quote stops being a guess.
HDMI and VGA are independent outputs, not a mirrored pair: the 21.5-inch panel shows the operation view while a second monitor beside it carries cameras, a manifest or a wall display. In a command hub that arrangement is cheaper and more flexible than a video wall controller, and it keeps the second screen at Full HD rather than stretching one image across two bezels.
Two limits worth stating. The second output mirrors nothing automatically — it is a separate desktop, so the software has to be told to open there. And cable length matters: beyond about five metres HDMI needs an active cable or an extender, which is a site decision, not a panel feature. Tell us the second screen distance and resolution.
There is no impeller in this chassis. Heat leaves through a flat sheet-metal backplate with louvred slots, by convection and radiation alone. That buys silence in a room where people sit all day, no fan drawing dust or metal fines into the electronics, and no filter to add to a maintenance round — the failure nobody schedules for. What it costs is headroom: passive cooling depends on the panel shedding heat into still air, so an open backplate in a 35 °C room is fine and the same unit sealed into an insulated enclosure is a different problem.
Compute runs Celeron J1900 through 12th-generation Core i7, with 4, 8 or 16 GB of memory and 128–512 GB of mSATA or M.2 NVMe storage plus a 1 TB 2.5-inch SATA bay. J1900 suits a single-pane dashboard or a browser client; i3 or i5 carries two to four live panes; i7 is for the console that renders a 3D plant, a camera preview and a database client at once. Because the chassis is fanless, that CPU choice is also a thermal choice: an i7 held at full load in a 45 °C room will clock down where an i5 will not. Tell us the software stack and the room temperature and the two get decided together.
The rear strip runs: DC input, HDMI, VGA on a blue DB15, four USB-A in two stacked pairs, one RJ45, mic and line-out jacks, and a metal power switch. Two blank plates at the left edge are the expansion positions for serial or additional network ports — they are cut when ordered, not populated as standard.
Typical wiring for a central console: the RJ45 to the plant switch, HDMI to the MES server display or a second monitor, VGA to a legacy panel, USB to keyboard, mouse and a camera, and the 9–36 V terminal where the cabinet supplies 24 V. Note that the standard build is a single Gigabit port; a hub on two segregated networks needs the second port ordered as an expansion.
The chassis is 537.0 wide, 328.0 high and 51.0 deep; the recommended opening is 529.0 × 320.0, leaving 4 mm of bezel on each side. VESA patterns of 75 × 75 and 100 × 100 are centred on the backplate, and snap-in clips are supplied for panel thicknesses from 1.0 to 6.0 mm.
At this size the opening is a joinery decision as much as an engineering one: a 529 mm hole in a stainless console is not something to discover is 2 mm out after laser cutting. Send the console drawing before fabrication and we will return the clearance and cable-exit check. Depth is 51 mm behind the front face plus bend radius for the VGA and DC leads.
The natural installation for this size is not a machine door but a workstation: two cantilever arms on a shared desk, one panel for the line view and one for the MES or camera wall. VESA 75 or 100 bolts straight to the backplate, the arm carries the load, and the desk stays clear of stands. Snap-in remains available where the console is a fabricated panel rather than furniture.
Arm selection is the risk. A 21.5-inch unit is heavier than the 15-inch monitor the arm was probably bought for, and a slowly sagging screen across a year is the failure mode. Give us the arm model, the reach and the desk height and we will confirm the load against the actual build weight. Tell us the console type and we will send the mounting drawing with it.
The installations this size goes into are consistent: a smart-factory digital-twin command centre, where a plant model is the main object on screen; a lithium-battery and solar central control station, where process trends and alarms dominate; a machine-vision main terminal, where an inspection image needs to be large enough to judge; and a cleanroom or food-grade workstation, where a fanless chassis is a contamination argument rather than a comfort one.
All four are built by integrators, so the ODM work is the product: custom I/O, brightness variant, the OS image with the customer's own shell, and the bezel carrying their brand. The cleanroom case also usually needs a documented convection path, and we can supply the thermal note for the customer's validation file. Tell us which of the four you are building and the volume, and the standard and customised quotes come back side by side.
Item | Specification |
|---|---|
Model | 21.5-inch Full HD fanless industrial panel PC |
Panel | 21.5" TFT LCD, IPS, 16:9, LED backlight |
Native resolution | 1920 × 1080 (Full HD), no scaling required for 1080P software |
Pixel density | Approx. 102 PPI |
Brightness | 350 cd/m² |
Viewing angle | 178° horizontal / 178° vertical (IPS) |
Surface | Anti-glare treatment, high-contrast bonding |
Touch | 10-point projected capacitive (PCAP) |
Touch behaviour | Glove operation, water-drop rejection |
Cover glass | Tempered glass, ≥7H hardness |
Processor | Intel Celeron J1900; Core i3 / i5 / i7, 3rd to 12th generation |
Memory | 4 GB / 8 GB / 16 GB (16 GB maximum) |
Storage | 128 / 256 / 512 GB mSATA or M.2 NVMe SSD + 1 TB 2.5" SATA bay |
Graphics | Integrated Intel HD Graphics |
Cooling | Fanless — flat sheet-metal backplate with louvred slots, convection only |
Network | 1 × Intel Gigabit Ethernet (RJ45); additional ports via expansion board |
USB | 4 × USB-A on rear panel |
Serial | None on standard rear panel; RS232 / RS485 via optional COM board |
Video output | 1 × HDMI + 1 × VGA, independent (dual-screen, not mirrored) |
Audio | 1 × mic in, 1 × line out |
Power input | DC 12 V standard; DC 9–36 V wide-range terminal optional |
Power draw | Quoted against the selected CPU (on request) |
Operating temperature | −20 to 60 °C, convection path required behind the panel |
Duty cycle | Continuous 7 × 24 h |
Ingress protection | IP65 front bezel; rear panel louvred, not rated |
Mounting | VESA 75 × 75 / 100 × 100; snap-in clips for 1.0–6.0 mm panels; desk stand |
Outline dimensions | 537.0 × 328.0 × 51.0 mm |
Panel cutout | 529.0 × 320.0 mm recommended (4 mm bezel per side) |
Net weight | Confirmed per configuration (on request) |
Operating system | Windows 7 / 10 / 11, Windows IoT, Linux (drivers per SKU) |
Meetneng traces its manufacturing back to 2008, and designs and builds in Shunde, Foshan, Guangdong — the district that supplies much of China's appliance and electronics industry. The plant covers 5,000 m², and the work is not assembled from someone else's boxes: sheet-metal fabrication, board-level integration, system assembly, burn-in and software imaging all happen on the same site. That is why a change to a port layout, a housing or a nameplate can be answered with a date rather than an introduction to a third party.
The product range covers industrial panel PCs, fanless industrial PCs, embedded computers, rugged tablets, industrial displays and commercial self-service terminals — panel-mount, VESA, DIN-rail, desktop and floor-standing formats from one factory. Quality control runs to ISO 9001 with twelve inspection points from incoming components to the final functional test, and the field repair rate is held under 0.5 % — a number that matters more than any single specification on any one of those pages.
Thirty-plus patents are held by the engineering team, covering thermal design, structural details and the interface between the electronics and the enclosure. Units are issued with CE, FCC, LVD and RoHS documentation against the exact bill of materials of the build you order, because changing a radio module or a power supply changes the test scope.
More than 15,000 customers in over 100 countries have bought from us, across industrial automation, energy, medical equipment, security, retail and logistics. Reference accounts include Haier, Gree, BYD, Hikvision, Foxconn and CRRC. Most of those relationships began with a single unit on a single line, which is the pattern we plan for: the first sample has to be right, because the second conversation depends on it.
Trade happens in person as well as over email. We take our own stands at international industrial and electronics fairs — the collage below is our booths across several shows — and the engineers who answer an enquiry are often the ones standing there, so a specification question tends to get an answer on the spot rather than a promise to check. Between shows, buyers come to Shunde to walk the line, sign off a sample and agree packaging. Tell us when you are travelling and we will hold a slot and a sample build for the same week.
OEM and ODM are the default way we work rather than an exception. The engineering team takes a requirement list — CPU or SoC, memory, port count, enclosure, logo, packaging, software image — and returns a configuration and a lead time. The nameplate, boot logo, gift box and manual are the parts most buyers start with, and the SDK or driver documents are released to the account that orders the sample.
Units ship by express and air freight with export documentation and industrial protective packaging; stocked configurations leave within 72 hours and built-to-order units follow the lead time on the quotation. Tell us the application, the destination country and the annual volume, and we will come back with a configuration, a landed-cost estimate and a sample plan.
No. This panel is 1920 × 1080 natively, which is the point of the size — 1080P software renders at 100 % scaling. If you need a lower resolution for legacy HMI software, the 15.6 or 18.5-inch models offer it. Tell us the software and we will point you at the right size rather than the biggest one.
It is fanless: a flat sheet-metal backplate with louvred slots, convection and radiation only. That suits quiet rooms, dusty halls and hygienic areas, and it removes the filter from your maintenance round. It does not suit a sealed enclosure with no convection path — tell us the enclosure and ambient temperature and we will confirm before you commit.
1920 × 1080 IPS at 350 cd/m² with a 178° viewing angle. Bright enough for a lit control room; not a sunlight-readable panel. If the console faces glazing, tell us and we will quote a high-brightness variant instead of letting you discover the limit on site.
Yes — HDMI and VGA are independent outputs, so the 21.5-inch panel can show the line view while a second Full HD monitor carries cameras or a manifest. The second screen is a separate desktop, so the software must be configured to open there. Tell us the distance and resolution of the second screen.
529.0 × 320.0 mm on a 537.0 × 328.0 mm chassis, leaving 4 mm of bezel per side. At this size the opening is worth checking before fabrication. Send us the console drawing and we will return the clearance and cable-exit check.
16 GB is the ceiling. For a single dashboard 8 GB is generous; for four live panes with a 3D scene and a camera preview, 16 GB with an i5 or i7 is the realistic configuration. Tell us how many panes are live and whether any is video and we will size it.
It can. Passive cooling has a thermal budget, and an i7 under sustained load at 45 °C ambient will clock down sooner than an i5 doing the same job. Choose the CPU for the workload and then check the room temperature — tell us both and we will quote the combination that holds.
One Gigabit RJ45 and no serial on the standard rear plate; both extra network ports and RS232 / RS485 come on an expansion board cut when ordered. A command hub on two segregated networks needs that second port specified. Tell us the network segments and the serial devices.
Yes. Bezel branding, custom I/O, brightness variants and a factory OS image are routine, and for cleanroom projects we provide the convection-path note for your validation file. Send the logo, the OS image and the annual volume.
Weight is confirmed per configuration because CPU and storage change it; warranty is stated on the quotation; CE and FCC documentation is supplied on request. Tell us the arm model if you are using one — an undersized arm is the most common installation failure at this size.