Most industrial panel PCs are maintained by opening something else. You unbolt the cabinet door, reach past a live terminal block, plug in a USB stick, and close it again — twice a shift if the line is being commissioned. This one puts a USB port and the power button on the front face, under an IP65 flap, so the door stays shut.
That single decision explains the rest of the design. At 10.4 inches and 3.54 kg it is the smallest panel in the range, which is what lets it go on a machine column rather than in a control room. 1024 × 768 across a 213.1 mm active area is 123 PPI — the densest panel we build — and two serial ports come as standard, because a compact machine panel almost always has a PLC and a drive to talk to.
| Availability: | |
|---|---|
GFACE-10.4"
Meetneng
A 10.4-inch 4:3 panel has 213.1 × 160.3 mm of active area. That is about 55 % of an A4 sheet, and it is the whole design constraint: you are not fitting a factory dashboard on it, you are fitting one station. Axis positions, a part count, three buttons and an alarm line. Everything else lives on a bigger screen somewhere else.
The category is worth being precise about. An industrial panel pc, as this page uses the term, has a sealed front, a DC input, a serial port and a duty rating measured in years, and it goes inside a machine enclosure. A commercial all-in-one or a shop kiosk shares the shape and none of that. If what you actually need is a kiosk, tell us — the cutout, the IP65 front and the serial ports are wasted money there.
That is a narrower brief than the widescreen pages in this range, and it changes what the panel has to be good at. Not distance legibility, not video walls — density, mounting, and access. The screen sits within arm's reach of an operator who is wearing gloves, standing at a machine, and has about four seconds to read it. Tell us the screen you are replacing and what has to stay on it, and we will say whether 10.4 inches holds it or whether you need the 15-inch 4:3.
Every USB update, every log pull, every power cycle on a machine panel normally means opening an enclosure that was sealed for a reason. On a machine tool that enclosure holds a VFD, a servo drive and a 24 V supply. Opening it to copy a log is a permit-to-work conversation in most plants, and it is the reason firmware updates get postponed until something fails.
Putting the port and the button on the front face removes that step. The flap is IP65-rated when closed, so the front seal is intact between visits; the two status LEDs next to the button give power and storage activity without opening anything. The honest caveat is the flap itself: an open cap is an IP65 front that is no longer IP65, and coolant will find it. Make closing the cap part of the shift routine, and tell us if the panel faces a washdown jet — we will quote a different front treatment.
The rear of this panel is one machined aluminium block with horizontal fins, and there is no fan anywhere in the build. Heat leaves the CPU through the block and into the air between the fins by convection alone. The fin stack is not decoration — it is the entire cooling system, which is why the housing is aluminium rather than sheet steel and why it weighs 3.54 kg for a 10-inch screen.
Convection has a direction. Mounted with the fins horizontal and the panel upright, air rises through the stack and the design works as drawn. Mounted flat on a bench face-up, or rotated so the fins run vertically, the chimney is blocked and the same panel runs hotter at the same load. Keep 50 mm of clear air behind the fins, keep them out of a closed cabinet pocket, and choose the CPU tier for the ambient you actually have. Tell us the mounting orientation and the summer temperature in that bay.
The chassis is 309 × 244.7 mm and the recommended opening is 301.0 × 237.0 mm. That leaves 4.0 mm of bezel on each side and 3.85 mm top and bottom, with R8 corners on the front bezel. Four millimetres is not enough to hide a wavy edge, and it is not enough to recover from a cut that wandered 2 mm.
Two practical consequences. The opening must be routed, laser-cut or punched from a template — a jigsaw and a file will show a bright line against the black glass. And the retention is not the bezel: it is eight M4 bosses on the 298 mm rear plate plus snap-in clips, so the cabinet needs clearance behind the panel as well as around it. Send us the cabinet drawing before it is cut and we will mark the 301 × 237 opening, the R8 corners and the clip positions.
1024 × 768 across 213 mm gives 123 PPI and a 0.206 mm pixel. At 0.5 m that resolves text down to about 4 pt, which means the panel will happily display a layout designed for a desktop monitor — and the operator will not be able to hit any of it with a glove. Density is only useful if the interface uses it to make fewer, larger elements, not more, smaller ones.
The working rule on this size: a gloved finger needs roughly 12 mm, so across 213 mm you get about 17 touch targets, not 30. Use the extra resolution to sharpen a drawing or a camera feed, not to add buttons. And if the machine is run in gloves all shift, say so at order time — the touch layer and the glass treatment are chosen for that, and we would rather quote the right one than have you find out on commissioning. Tell us what the operator wears and how far away they stand.
The bottom edge carries two DB9 serial ports as standard, expandable to six. That is the highest serial count in this range at the smallest size, and it is not an accident: the panels that get replaced by a 10.4-inch unit are usually driving a PLC on RS485 and an inverter or a barcode reader on RS232 at the same time, with the Ethernet port going up to MES.
RS232 and RS485 are not interchangeable on the same port, so the order has to say which is which — the rear label marks COM1 as 232/485 selectable and the rest per configuration. The same edge also carries DC 12 V, HDMI, VGA, four USB-A in two stacked pairs, one RJ45 and mic / line-out. Send us the device list with the protocol for each port and we will map it before the panel is built, not after it is in the cabinet.
At 3.54 kg this panel hangs on a standard 75 × 75 or 100 × 100 VESA plate with four M4 screws. Each screw carries under 20 N in shear at that weight, which is well inside what an M4 in an aluminium boss will take — so a light cantilever arm or a monitor stand is sufficient, and no one has to weld a bracket to the machine frame.
Four mounting routes come out of that: a desktop stand for a bench or a console top, the 301 × 237 mm embedded cutout for a cabinet face, a plain wall plate, and a cantilever arm for a column or a machine guard. The desktop stand is worth pointing out because it is the option most retrofit projects actually want — a panel on a stand beside a machine needs no sheet-metal work at all. Tell us which surface it is going on and how much reach the operator needs.
Four applications recur. A CNC milling or turning centre, where the panel replaces a mono HMI and has to show axis positions and a toolpath. A laser marking station, where it shows a camera image and a job list. A glue dispensing or packaging cell, where it shows a pass/fail count. And a warehouse or AGV dispatch point, where it is a fixed terminal on a wall.
The common thread is that the panel is part of the machine, not part of the office. That means the buyer is usually a machine builder or a systems integrator, the quantities are five to fifty, and the requirements arrive as a drawing rather than a shopping list. If that is your situation, send the drawing and the device list — the quote comes back with the cutout, the serial mapping and the CPU tier already settled.
The range is unusually wide for a 10-inch panel, and the bottom of it is still useful. A Celeron J1800 with a single LAN or a J1900 with two will run a WinCC or InTouch runtime and a browser tab all day, fanless, on 4 GB. Above that come 3rd to 8th-generation mobile Core parts — i5-3210M, i3-5005U, i5-5350U, i7-5600U, i5-6300U, i3-7100U, i5-7300U, i3-8130U, i5-8250U, i7-8550U — and at the top a 12th-generation i5-1235U with a 32 GB ceiling.
Two variants are worth knowing about before you specify. The quad-GbE builds (i5-7200U, i5-8250U or i7-8550U with four LAN ports) exist for vision and multi-camera cells, where one panel sits between several network segments. And DDR3 versus DDR4 follows the CPU generation, not the order form — so a memory upgrade later means matching the board you bought. Tell us the software stack and how many cameras or network segments it touches, and we will name the cheapest tier that will not be replaced in two years.
First the front access: does the front need USB only, or USB and the power button, or neither — a sealed front with no flap is cheaper and has one less thing to leave open. Second the serial map, because RS232 and RS485 are fixed at build. Third the mounting surface, which decides whether you need a stand, a cutout or an arm. The CPU, memory and storage are the easiest things to change and the last things to argue about.
We quote the standard build and the customised build side by side so the difference is visible rather than buried. Send us the machine drawing, the device list with protocols, and the ambient temperature in the bay, and the quote comes back with those three answered.
Item | Specification |
|---|---|
Model series | GFACE 10.4" — front-access 4:3 industrial panel pc |
Display size | 10.4 inch TFT LCD, 4:3 |
Native resolution | 1024 × 768 (XGA) |
Active area | 213.1 × 160.3 mm |
Pixel density | 123 PPI, 0.206 mm pixel pitch |
Viewing angle | On request, quoted against the selected panel |
Brightness | On request — quoted against the selected panel |
Contrast | On request, quoted against the panel batch |
Touch technology | Optional; resistive or projected capacitive, selected for glove use |
Cover surface | Tempered glass or hard-coated film per touch option |
Front controls | Power switch, 2 × status LED (power / storage), 1 × front USB-A under IP65 cap |
Processor | Celeron J1800 (1 LAN) / J1900 (2 LAN); Core i5-3210M; i3-5005U, i5-5350U, i7-5600U; i5-6300U; i3-7100U, i5-7300U; i3-8130U, i5-8250U, i7-8550U; i5-1235U |
Quad-GbE variants | i5-7200U, i5-8250U or i7-8550U with 4 × LAN |
Memory | 4 / 8 / 16 GB DDR3 or DDR4 per CPU generation; 32 GB on the 12th-generation board |
Storage | 128 / 256 / 512 GB mSATA or M.2 NVMe SSD + 1 TB 2.5" SATA bay |
Graphics | Integrated Intel HD / UHD Graphics |
Network | 1 × RJ45 standard (2 × on J1900); 4 × RJ45 on quad-GbE variants |
Serial | 2 × DB9 standard (RS232 / RS485 assigned per port); expandable to 6 |
USB | 1 × front USB-A + 4 × rear USB-A |
Video output | 1 × HDMI + 1 × VGA |
Audio | 1 × mic in, 1 × line out |
Power input | DC 12 V |
Power draw | Quoted against the selected CPU (on request) |
Operating temperature | On request — quoted against the CPU tier and mounting orientation |
Cooling | Fanless; machined aluminium horizontal finned heat sink |
Duty cycle | Continuous 7 × 24 h |
Ingress protection | IP65 front incl. closed front cap; rear finned body ventilated, not rated |
Mounting | VESA 75 × 75 and 100 × 100; desktop stand, embedded, wall, cantilever |
Outline dimensions | 309 × 244.7 × 58.0 mm |
Panel cutout | 301.0 × 237.0 mm, R8 front bezel corners |
Mass | Approx. 3.54 kg, pure aluminium housing |
Operating system | Windows 7 / 10 / 11, Windows IoT, Linux (drivers per SKU) |
Meetneng traces its manufacturing back to 2008, and designs and builds in Shunde, Foshan, Guangdong — the district that supplies much of China's appliance and electronics industry. The plant covers 5,000 m², and the work is not assembled from someone else's boxes: sheet-metal fabrication, board-level integration, system assembly, burn-in and software imaging all happen on the same site. That is why a change to a port layout, a housing or a nameplate can be answered with a date rather than an introduction to a third party.
The product range covers industrial panel PCs, fanless industrial PCs, embedded computers, rugged tablets, industrial displays and commercial self-service terminals — panel-mount, VESA, DIN-rail, desktop and floor-standing formats from one factory. Quality control runs to ISO 9001 with twelve inspection points from incoming components to the final functional test, and the field repair rate is held under 0.5 % — a number that matters more than any single specification on any one of those pages.
Thirty-plus patents are held by the engineering team, covering thermal design, structural details and the interface between the electronics and the enclosure. Units are issued with CE, FCC, LVD and RoHS documentation against the exact bill of materials of the build you order, because changing a radio module or a power supply changes the test scope.
More than 15,000 customers in over 100 countries have bought from us, across industrial automation, energy, medical equipment, security, retail and logistics. Reference accounts include Haier, Gree, BYD, Hikvision, Foxconn and CRRC. Most of those relationships began with a single unit on a single line, which is the pattern we plan for: the first sample has to be right, because the second conversation depends on it.
Trade happens in person as well as over email. We take our own stands at international industrial and electronics fairs — the collage below is our booths across several shows — and the engineers who answer an enquiry are often the ones standing there, so a specification question tends to get an answer on the spot rather than a promise to check. Between shows, buyers come to Shunde to walk the line, sign off a sample and agree packaging. Tell us when you are travelling and we will hold a slot and a sample build for the same week.
OEM and ODM are the default way we work rather than an exception. The engineering team takes a requirement list — CPU or SoC, memory, port count, enclosure, logo, packaging, software image — and returns a configuration and a lead time. The nameplate, boot logo, gift box and manual are the parts most buyers start with, and the SDK or driver documents are released to the account that orders the sample.
Units ship by express and air freight with export documentation and industrial protective packaging; stocked configurations leave within 72 hours and built-to-order units follow the lead time on the quotation. Tell us the application, the destination country and the annual volume, and we will come back with a configuration, a landed-cost estimate and a sample plan.
A power switch, two status LEDs for power and storage activity, and one USB-A port, all under an orange IP65 protective cap. The idea is that a firmware update or a log download happens without opening the electrical cabinet. Tell us whether you need the USB only or the switch as well — both are build options and a sealed front without the flap is cheaper.
No. IP65 applies with the cap closed; an open cap is an opening in the front face. That is true of every front-access panel on the market and it is worth planning for: make closing the cap part of the shift routine, and if the panel faces a washdown jet, tell us so we can quote a different front treatment rather than let you find out.
It is a knock-out in the bottom edge for a cable gland or compression fitting, so a field cable bundle can enter the housing without using a connector. It is the right way to bring in a multi-core signal cable that has no plug on the end. Send us the cable diameter and the number of cores and we will specify the gland with the panel.
If the old HMI was 1024 × 768, yes — the same layout lands pixel for pixel with no stretching. If it was 800 × 600 the image will letterbox or scale, and if it was a proprietary controller screen the runtime is the real question, not the panel. Tell us the old model and the software and we will say what transfers and what has to be rebuilt.
Two DB9 ports standard, up to six on request. The rear label marks COM1 as RS232 / RS485 selectable and the others are assigned at build. Send the device list with the protocol for each port — a PLC on RS485 and a barcode reader on RS232 is the common pairing — and we will map it before the panel is assembled. Send us the device list and we will map the ports on the drawing.
That depends on the touch option, and the touch option is chosen at order. A gloved finger needs a target around 12 mm, which is about 17 targets across this screen — so the interface has to be designed for it, not just the hardware. Tell us what the operator wears and whether the machine is run wet; we will quote the matching touch layer and glass.
Use the desktop stand or a VESA 75 / 100 arm. At 3.54 kg the load is under 20 N per M4 screw, so a standard monitor arm is enough and nothing needs welding. The embedded route needs a 301.0 × 237.0 mm routed opening with R8 corners, which is a fabrication job, not a field job. Tell us the surface and we will recommend the cheapest of the four.
It limits the sustained load, not the model list — the whole range is offered fanless because the aluminium block is sized for it. What changes is the ambient the panel tolerates at each tier: a 12th-generation i5 in a 45 °C bay is a different proposition from a J1900 in the same bay. Tell us the summer temperature at the mounting point and the duty cycle, and we will cap the CPU tier accordingly.
Yes, and that is one of the better uses of it — a keyboard and a USB stick for a BIOS change or an image restore without opening the cabinet. It is a USB-A host port, so a barcode scanner or a programming dongle works the same way. Tell us what gets plugged in and how often, because a port in weekly use wants a different cap routine from one used twice a year.
Three things: the machine or cabinet drawing, the device list with the protocol for every port, and the ambient temperature at the mounting point. Add the touch requirement and the CPU tier if you have a preference. With those we quote the standard build and the customised build side by side, with the cutout, the serial map and the mounting already answered. Send us those three and the first reply is a quote, not a question.